Building Envelope

Rain intrusion testing, done to standard

Water coming in from outside is a different problem from water escaping a pipe inside, and it needs a different method. We test the envelope under controlled, repeatable conditions to the published standards, and tell you which component is actually letting water through.

ASTM certifiedTesting performed to published ASTM and AAMA methods
LevelsSpray test through to full ASTM E2128 investigation
DeliverableDocumented report, written to support a claim
CoverageSan Antonio and Austin metros

When to call us

  • Staining or damp below windows only after driving rain
  • A leak that appears in storms but never when you run a hose
  • Water at curtain wall or storefront joints
  • Balcony, deck, or plaza leaks into the space below
  • New construction you want proven before handover
  • A warranty, insurance, or litigation claim that needs documented evidence

Need this today?

A person answers Monday to Friday, 7:00a–6:00p, and you get the price before any work starts.

(830) 816-0665
Levels of testing

How far you need to go

Rain testing is a ladder, not one product. Each rung costs more and proves more, and the right answer depends on what the result has to do — satisfy your own curiosity, satisfy a specification, or survive a dispute.

Level 01

Diagnostic spray test

Directional water · no instrumentation

Does water get in around here at all?

A controlled hose test working from the bottom up, one element at a time. Fast and inexpensive, and often all that is needed when there is one obvious suspect. It is not a standardized method, so it will not satisfy a specification or support a claim — treat it as a first look that tells us where to point the instrumented testing.

Typically used forA single suspect location · budget-constrained first pass · confirming a repair held

Level 02

Calibrated spray to AAMA 501.2

AAMA 501.2

Do the sealed joints and fixed glazing leak?

A calibrated nozzle at a specified pressure, traversed along the joint at a specified rate. Because the water application is controlled and repeatable, the result means something to a third party. It applies to sealed, non-operable assemblies — storefront, curtain wall, sloped glazing — and it is the right tool for checking sealant and glazing joints, including as quality control on newly installed work.

Typically used forStorefront and curtain wall joints · new sealant QC · fixed glazing

Level 03

Chamber testing to ASTM E1105

ASTM E1105 · uniform or cyclic static air pressure difference

Does this assembly leak under the wind-driven conditions it was designed for?

A spray rack delivers water at a specified rate while a sealed chamber on the interior applies a pressure differential across the assembly. That differential is the point: wind-driven rain does not fall on a building, it is pushed into it, and an assembly that passes a gravity spray test can still fail under pressure. This is the test that project specifications normally name, and the one that tests operable windows and doors meaningfully.

Typically used forSpecification compliance · operable windows and doors · new construction acceptance · warranty disputes

Level 04

Forensic investigation to ASTM E2128

ASTM E2128

Why does this building leak, and what will actually fix it?

The full methodology rather than a single test: design and shop drawing review, service and repair history, exterior condition survey, then targeted testing drawn from the levels above, then analysis. This is what you want when a building has had several repairs that did not hold, because the answer is usually that everyone has been testing the wrong element. It is also the level that stands up when the matter is already in dispute.

Typically used forRecurring unexplained leaks · repeated failed repairs · litigation and insurance claims

Alongside

Assembly-specific methods

These are not rungs on the ladder — they apply to particular assemblies and are chosen by what is being tested rather than by how conclusive you need the answer to be.

ASTM C1601

Water penetration of masonry wall surfaces — brick, block, and stone veneer, tested as a wall area rather than a joint.

ASTM D5957

Flood testing of horizontal waterproofing — balconies, decks, planters, and plaza areas, dammed and held to depth.

How we work

What the job actually involves

  1. 01

    Review before we test

    ASTM E2128 is a methodology, not a spray test — it starts with the drawings, the age and type of assembly, and the leak history. Testing without that context tells you a wall leaks, which you already knew.

  2. 02

    Test to the applicable standard

    AAMA 501.2 for sealed joints and glazing on fixed systems. ASTM E1105 with a chamber and spray rack where a pressure differential is required. ASTM C1601 for masonry wall surfaces. ASTM D5957 flood testing for balconies, decks, and horizontal waterproofing. Which one applies depends on the assembly, and we will tell you why before we quote.

  3. 03

    Isolate component by component

    The value is not "it leaks" — it is knowing whether it is the head seal, the sill, the joint between systems, or the wall above. We mask and test in sequence so each result implicates one element.

  4. 04

    Report you can act on

    Photographs, water application rates, pressures, durations, and a clear pass or fail per location. Written so a contractor can scope a repair from it, and so it holds up if the conversation becomes a claim.

Central Texas

Why this looks different here

Central Texas produces envelope failures for reasons that have little to do with rainfall totals. Wind-driven rain during spring and fall storms pushes water uphill into assemblies designed for gravity. Hail damages sealant, coatings, and flashings without leaving anything visible from the ground. And an enormous volume of stucco, EIFS, and masonry veneer went up fast during the growth of the last two decades, where the detailing at penetrations and transitions is exactly where testing tends to find the failure.

What drives the price

  • Which standard the assembly and your purpose actually require
  • Number of test locations, and whether each needs isolating separately
  • Access — ladders, lifts, swing stage, or scaffold
  • Spray-only testing versus chamber testing with a pressure differential
  • Report depth, and whether it needs to support a warranty or legal claim

Every option is quoted flat-rate and approved by you before work begins.

Questions

Straight answers

How is this different from a plumbing leak?

Direction. A plumbing leak is water escaping a supply or drain line inside the building, and it happens whether or not it is raining. Rain intrusion is water entering from outside through the envelope — windows, doors, curtain wall, masonry, roofing transitions, balconies. If a stain only appears after a storm, and never when the weather is dry, it is almost certainly the envelope rather than the plumbing.

Which level do I need?

If you have one obvious suspect and want a quick answer, start at the spray test. If a specification, a contract, or a warranty is involved, it almost certainly names ASTM E1105 and nothing below it will satisfy them. If the building has already had repairs that did not hold, go to the E2128 investigation — repeating a test on the element someone already replaced is how buildings end up on their fourth failed repair. Tell us the purpose and we will tell you the lowest level that actually answers it.

Which standard do I need?

It depends on the assembly and on what the result has to support. AAMA 501.2 is a field check of sealed joints on fixed glazing. ASTM E1105 applies a controlled pressure differential and is what specifications usually call for on windows and curtain wall. ASTM C1601 covers masonry wall surfaces. ASTM D5957 is flood testing for horizontal waterproofing. Tell us the purpose and we will tell you which applies.

Can you repair what you find?

We can scope and coordinate the repair, and for the plumbing-side elements we do the work ourselves. Envelope remediation — sealant, flashing, glazing, waterproofing — is specialist work and we will tell you plainly which parts we self-perform and which we bring in a specialist for.

Will the report support a warranty or insurance claim?

That is what it is written for. Test conditions, water rates, pressures, durations, and photographs are all recorded per location, because a report that only says "leaks" is not evidence. If the matter is already in dispute, tell us at the outset — it changes how we document.

Do you test new construction before handover?

Yes, and it is the cheapest time to do it. Finding a systemic detailing problem on a mock-up or the first few units, before the same detail is repeated across the building, saves an order of magnitude over finding it in year three.

Get it looked at properly.

Call and talk to a person, or book a visit online. Either way you see the price before we start.